Search:

Type: Posts; User: cvrettacos

Page 1 of 4 1 2 3 4

Search: Search took 0.02 seconds.

  1. Got the unit squared away. I had forgotten about...

    Got the unit squared away. I had forgotten about the FORCE BOOTLOADER MODE function in Maintenance Tool. Wolfgang was kind enough to point it out to me yesterday.
  2. Customer sent me the Cr0403. I'm running...

    Customer sent me the Cr0403. I'm running Maintenance V03.03.06 & I'm getting that same error. It comes up immediately when I try READ CH PARAM. I can do IDENTITY & it'll update (software version...
  3. The Cr0403 has a date code of "AC". Didn't have...

    The Cr0403 has a date code of "AC". Didn't have them try to read the Identity, but did have them try to Read Channel Parameters, that's when the error message comes up. Same customer, using same...
  4. Maintenance Tool Issue w/ PEAK Adapter: BMAS_ERROR_SUB_SERVICE_UNKNOWN

    We've got a customer who's running Maintenance_3.4.6.359903.314 & gets a BMAS_ERROR_SUB_SERVICE_UNKNOWN when trying to connect to a Cr0403. They can use they PEAK adapter w/ CoDeSys to connect the...
  5. Thread: DBC file

    by cvrettacos
    Replies
    2
    Views
    903

    Ok, thanks.

    Ok, thanks.
  6. Thread: DBC file

    by cvrettacos
    Replies
    2
    Views
    903

    DBC file

    We've got a customer that's asking for *.DBC files for a project that uses a Cr2530 & Cr1084. Is there a way to create these data base files, or something similar, in CoDeSys 2.3? Thanks.
  7. I uninstalled the Sieca and Sontheim items &...

    I uninstalled the Sieca and Sontheim items & reinstalled Maintenance Tool before reading your response & it ended up fixing my issue. I can now use the PEAK adapter again to connect with Maintenance...
  8. I was originally using a PEAK. Tried the CANfox...

    I was originally using a PEAK. Tried the CANfox & it works fine. I am running version 7.4.44.0 of the CANfox MT API. Is it still worth uninstalling/reinstalling the Seica or Sontheim stuff for the...
  9. Same thing happens in CAN utility & with other...

    Same thing happens in CAN utility & with other Basic devices. I think something just got hosed with my computer, but re-installing Maintenance Tool isn't resolving the issue.
  10. RSA - Invalid Key / CAN controller not available error

    Getting the following pop-ups whenever I try to use Maintenance Tool (release V03.03.06.347696.350) to connect to a Cr2532. I uninstalled & re-installed Maintenance Tool without any luck. No issues...
  11. Replies
    1
    Views
    1,310

    My issue was the driver for the ecomatmobile...

    My issue was the driver for the ecomatmobile virtual interface. Updated it to v2.12.0.0 & USB now works with V030002 firmware.
  12. Replies
    2
    Views
    1,028

    Yes, that's the only way I can connect using...

    Yes, that's the only way I can connect using v0300002. Hardware looks to be AK 170G.
  13. Replies
    2
    Views
    1,028

    Cr0032 won't load Boot Project

    Can't get a Cr0032 (v0300002) to load the boot project. It looks normal through the entire process, but after the download status screen shows the entire boot project has been loaded I get a...
  14. Replies
    1
    Views
    1,310

    Cr0032 USB Comm Issue w/ V030002

    Can't connect to Cr0032 via USB with firmware version V030002, but can with V020106. The programming manual indicates different baud rates depending on the firmware versions (115200 for <V03.00.00 /...
  15. Jeremy, That was the issue. Missed your reply...

    Jeremy,
    That was the issue. Missed your reply while I was typing mine. Thanks for the response.
  16. Figured it out, only had one CANopen Master in...

    Figured it out, only had one CANopen Master in PLC Configuration. Needed to add two MOREto use CAN3 as master (screen shot attached).

    368
  17. ifm_CR0032_CANopenXMaster_V020101.lib Error 4114

    Trying to use CAN3 on Cr0032 as CANopen master. Wanted to use CAN3_MASTER_STATUS function block, so added ifm_CR0032_CANopen3Master_V020101.lib. This results in 97 instances of Error 4114 "One of...
  18. Replies
    5
    Views
    2,702

    The CONFIG input variable of CAN1_RECEIVE should...

    The CONFIG input variable of CAN1_RECEIVE should not be constantly set TRUE. It only needs to be TRUE for one cycle to configure/initialize the FB.

    Also, I don't think you want to keep the CLEAR...
  19. Replies
    9
    Views
    3,336

    Hey Erik, 5HZ LED starts as soon as I switch...

    Hey Erik,

    5HZ LED starts as soon as I switch power on. Display never gets around to loading the application now. I tried, but can't connect using FTP. Time for a RMA?
  20. Replies
    9
    Views
    3,336

    Cr1082 Stuck in Boot Process

    I loaded a Cr1084 application into a Cr1082 (because that's all I had available for testing). After about 2-3 minutes of running I got a 2 Hz RED LED (run with error). The unit now appears to be...
  21. Thanks for the feedback

    Thanks for the feedback
  22. Controlled Shutdown of Cr0233 using SUPPLY_SWITCH

    Working on a project where the customer wants to kill power to the control system if the machine is left idle for a specified time period. Is there any issue/concern with running the machine by...
  23. The problem was discovered when an end user...

    The problem was discovered when an end user disconnected the Deutsch connector in the field & the engine unexpectedly cranked. Don't know why the supply +V & -V were run through separate connectors...
  24. Cr0401/Cr0403 Unintended Output Energization

    I’ve discovered an issue with the outputs on the basic controllers (both Cr0401 & Cr0403) that’s resulting in the unintended cranking of an engine when power is assumed to be disconnected from...
  25. Replies
    2
    Views
    2,930

    Thanks for the info.

    Thanks for the info.
Results 1 to 25 of 87
Page 1 of 4 1 2 3 4