Search:

Type: Posts; User: is_razi

Search: Search took 0.01 seconds.

  1. sample project for io field selection and editing using encoder of CR1080

    hi everybody,
    can somebody give me a sample project about selection between some io fieldes and editing the value of selected field using encoder of CR1080 panel,please.
    i mean rotating the knob to...
  2. Dear jeremy your guidances helped me much....

    Dear jeremy
    your guidances helped me much.
    thank you for considering my requests.
  3. Replies
    4
    Views
    5,683

    Hi there, Can somebody give me sample code or...

    Hi there,
    Can somebody give me sample code or any information for implementing a simple alarm system in CR1080 please?
    I'm really in trouble with that.
    Thanks for you considerations.
  4. Dear jeremy, Can i feed the occ block from a PID...

    Dear jeremy,
    Can i feed the occ block from a PID block by just scaling the output of PID block(0~65535) to the current range of the coil(0~85mA)?
    And will not be there any conflict between the OCC...
  5. so do you think that i must neglect the JOYSTICK...

    so do you think that i must neglect the JOYSTICK and OCC blocks and recondition the input signal of the joystick input myself and supply it beside the outputs of the PID blocks through a multiplexer...
  6. Replies
    4
    Views
    5,683

    hi, do you mean that i need to define some text...

    hi,
    do you mean that i need to define some text fields and show the messages there .can you give me a code example for doing so please.
    sorry but i'm new to ecomat PLCs and HMI's so i really need...
  7. thanks for your response the problem that I have...

    thanks for your response
    the problem that I have is that I must control single PWM channel in 3mode corresponding to the operator choice
    1-through a joystick function manually
    2-a closed loop for...
  8. info request for controlling a PWM Channel through multi points

    Hi there,
    I intend to control a PWM hydropump in 3 way using a single PWM channel of CR0020 PLC :
    1-Control manually using a joystick
    2-Closed loop control with the hydromotor(which is supplied...
  9. Replies
    4
    Views
    5,683

    alarm configuration in CR1080 panel

    hi everybody,
    i have a problem with cr1080 panels please help me to figure it out.
    As you know there is an alarm configuration and alarm table element for R360 PLCs(type that i intend to use is...
Results 1 to 9 of 9