    Controller Not Holding Program

    Has anyone ever had it where the controller won't hold a program after a power cycle? I've got a CR0032 on my desk that forgets the program that it has loaded everytime I power cycle it. I can go...
  3. Replies
    1
    Views
    8,624

    Finding IO Addresses

    Just found something that may be of use to others. If you open the .cfg file for the piece of hardware you are using (for example, ifm_CR0032_V02.cfg) with Notepad you will find the following (for...
  4. Replies
    6
    Views
    12,167

    I'm apparently really slow because I'm still...

    I'm apparently really slow because I'm still confused.


    How do I set (in Codesys) what CAN port I'm using (1-4)?
    How do I set (in Codesys) the output type (digital, analog, ...)?
    How do the...
  5. Replies
    6
    Views
    12,167

    I wasn't aware that the CR2511 was an inferior...

    I wasn't aware that the CR2511 was an inferior product.

    I've already added it to the CANopen Master. I was wondering how I would go about addressing the 8 outputs on the slave IO module once that...
  6. Replies
    6
    Views
    12,167

    Also, what does this mean and what do I do with...

    Also, what does this mean and what do I do with it?


    Warning 1902: 'C:\...\CR2511_C.hex': The library is not suitable for the current machine type or errant!
  7. Replies
    6
    Views
    12,167

    CR0032 and CR2511

    How does one properly configure a CR2511 to talk with a CR0032? I've added CR2511_C.lib to my libraries and added the CR2511 EDS under CANopen Master on my PLC Configuration page. I've also created...
  8. Replies
    2
    Views
    4,453

    What would be a good place to purchase these?

    What would be a good place to purchase these?
  9. Replies
    1
    Views
    3,740

    "NORM_DINT" Function

    Is it just me or is the NORM_DINT function missing from the ifm_CR0403 library? See the attached PDF of screenshots.
  10. Replies
    3
    Views
    5,103

    Never mind. The block is a Function Block and...

    Never mind. The block is a Function Block and will be individualized for each SA/device.
  11. Replies
    3
    Views
    5,103

    Jeremy, Am I correct in reading the below...

    Jeremy,

    Am I correct in reading the below excerpt as this program will have COMM_ERRORs if there are more than one keypad on a system (and thus, multiple source addresses)?


    IF...
  12. Replies
    1
    Views
    6,629

    CR0403 and J1939

    In the manual for the CR0403 it lists:



    Which (CAN1/CAN2) interface is this referring to? Am I able to use J1939 on either? Can I use J1939 (with a Grayhill keypad) on the same channel as...
  13. Replies
    3
    Views
    5,103

    As a FYI, you may need to add the...

    As a FYI, you may need to add the "ifm_J1939_2_Vxxyyzz.LIB" library to compile the export (at least I did)
  14. Thread: Pop Up Window

    by Keshik
    Replies
    5
    Views
    4,883

    How do you do that? I read something about being...

    How do you do that? I read something about being able to load visualizations inside each other but how do you do that?
  15. Thread: CR0451 EDS File

    by Keshik
    Replies
    4
    Views
    5,350

    I am using network variables. I was under the...

    I am using network variables. I was under the impression that I needed to add the display as a slave in order to be able to have it in the network. What template should I use for the display if I...
  16. Replies
    5
    Views
    5,112

    I'm using a PWM1000 block and not an OUTPUT...

    I'm using a PWM1000 block and not an OUTPUT block. I'm trying to do an analog out, not a digital. This is on my output.

    On my input I'm using "IN_BINARY_LOW" on channel 2.
  17. Thread: CR0451 EDS File

    by Keshik
    Replies
    4
    Views
    5,350

    CR0451 EDS File

    Is there an EDS file available for the CR0451 to be used as a slave?
  18. Thread: Pop Up Window

    by Keshik
    Replies
    5
    Views
    4,883

    You make it sound like this isn't a typical way...

    You make it sound like this isn't a typical way of doing things. What are other people doing for alert messages and error warnings? Thanks.
  19. Replies
    3
    Views
    6,424

    Thanks Jeremy. Another question: when you add a...

    Thanks Jeremy. Another question: when you add a slave element under the "PLC Configuration" section, it automatically adds the Receive PDO-Mapping, Send PDO-Mapping, and Service Data Objects tabs. Do...
  20. Replies
    3
    Views
    6,424

    CANOPEN Master/Slave Networks

    Hi,

    I was wondering if someone could layout best practices for network topology in terms of setting masters and slaves. Can I have more than one master on a CANOPEN network? In a CR0403/CR0451...
  21. Thread: Pop Up Window

    by Keshik
    Replies
    5
    Views
    4,883

    Pop Up Window

    Is there a good way to create a pop up window that will appear on any visualization page during operation? I'm thinking of an error message indicating a low oil level situation.
  22. Replies
    5
    Views
    5,112

    It has these two entries under PWM1000 in the...

    It has these two entries under PWM1000 in the CR0403:


    141 8D wire break occurred
    142 8E short to supply voltage occurred

    Also, I'm not having any luck with the INPUT block error detection. I...
  23. Replies
    5
    Views
    5,112

    Broken Wire Detection

    Hi. I'm using a CR0403 and am trying to detect a broken wire condition. I'm using a PWM1000 block to drive a LED. Whenever I remove the wire from the LED the RESULT doesn't change from "1". Shouldn't...
  24. Replies
    1
    Views
    3,287

    Kind of a misleading title, don't you think? ...

    Kind of a misleading title, don't you think?

    See the attached manual for the CR0451.
Results 1 to 24 of 24