Got the unit squared away. I had forgotten about the FORCE BOOTLOADER MODE function in Maintenance Tool. Wolfgang was kind enough to point it out to me yesterday.
Type: Posts; User: cvrettacos
Got the unit squared away. I had forgotten about the FORCE BOOTLOADER MODE function in Maintenance Tool. Wolfgang was kind enough to point it out to me yesterday.
Customer sent me the Cr0403. I'm running Maintenance V03.03.06 & I'm getting that same error. It comes up immediately when I try READ CH PARAM. I can do IDENTITY & it'll update (software version...
The Cr0403 has a date code of "AC". Didn't have them try to read the Identity, but did have them try to Read Channel Parameters, that's when the error message comes up. Same customer, using same...
We've got a customer who's running Maintenance_3.4.6.359903.314 & gets a BMAS_ERROR_SUB_SERVICE_UNKNOWN when trying to connect to a Cr0403. They can use they PEAK adapter w/ CoDeSys to connect the...
Ok, thanks.
We've got a customer that's asking for *.DBC files for a project that uses a Cr2530 & Cr1084. Is there a way to create these data base files, or something similar, in CoDeSys 2.3? Thanks.
I uninstalled the Sieca and Sontheim items & reinstalled Maintenance Tool before reading your response & it ended up fixing my issue. I can now use the PEAK adapter again to connect with Maintenance...
I was originally using a PEAK. Tried the CANfox & it works fine. I am running version 7.4.44.0 of the CANfox MT API. Is it still worth uninstalling/reinstalling the Seica or Sontheim stuff for the...
Same thing happens in CAN utility & with other Basic devices. I think something just got hosed with my computer, but re-installing Maintenance Tool isn't resolving the issue.
Getting the following pop-ups whenever I try to use Maintenance Tool (release V03.03.06.347696.350) to connect to a Cr2532. I uninstalled & re-installed Maintenance Tool without any luck. No issues...
My issue was the driver for the ecomatmobile virtual interface. Updated it to v2.12.0.0 & USB now works with V030002 firmware.
Yes, that's the only way I can connect using v0300002. Hardware looks to be AK 170G.
Can't get a Cr0032 (v0300002) to load the boot project. It looks normal through the entire process, but after the download status screen shows the entire boot project has been loaded I get a...
Can't connect to Cr0032 via USB with firmware version V030002, but can with V020106. The programming manual indicates different baud rates depending on the firmware versions (115200 for <V03.00.00 /...
Jeremy,
That was the issue. Missed your reply while I was typing mine. Thanks for the response.
Figured it out, only had one CANopen Master in PLC Configuration. Needed to add two MOREto use CAN3 as master (screen shot attached).
368
Trying to use CAN3 on Cr0032 as CANopen master. Wanted to use CAN3_MASTER_STATUS function block, so added ifm_CR0032_CANopen3Master_V020101.lib. This results in 97 instances of Error 4114 "One of...
The CONFIG input variable of CAN1_RECEIVE should not be constantly set TRUE. It only needs to be TRUE for one cycle to configure/initialize the FB.
Also, I don't think you want to keep the CLEAR...
Hey Erik,
5HZ LED starts as soon as I switch power on. Display never gets around to loading the application now. I tried, but can't connect using FTP. Time for a RMA?
I loaded a Cr1084 application into a Cr1082 (because that's all I had available for testing). After about 2-3 minutes of running I got a 2 Hz RED LED (run with error). The unit now appears to be...
Thanks for the feedback
Working on a project where the customer wants to kill power to the control system if the machine is left idle for a specified time period. Is there any issue/concern with running the machine by...
The problem was discovered when an end user disconnected the Deutsch connector in the field & the engine unexpectedly cranked. Don't know why the supply +V & -V were run through separate connectors...
I’ve discovered an issue with the outputs on the basic controllers (both Cr0401 & Cr0403) that’s resulting in the unintended cranking of an engine when power is assumed to be disconnected from...
Thanks for the info.