Search:

Type: Posts; User: Erik Gerrits

Page 1 of 13 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    106

    Yes if you use the V02xxxx firmware. It has a...

    Yes if you use the V02xxxx firmware. It has a PDF viewer in the new release.
  2. Replies
    1
    Views
    154

    I would run with the newest version of the...

    I would run with the newest version of the firmware. There is full Modbus support in V3.1.0.6.
  3. Replies
    1
    Views
    629

    You have to use the DM1_Read function block from...

    You have to use the DM1_Read function block from the IoDrivJ1939 library from Codesys.
  4. Replies
    2
    Views
    888

    Yes just take a look into the manual. There are...

    Yes just take a look into the manual. There are no buttons so you either have to put it into the setup mode via the Service pins or you can have a function block call that put the display into setup...
  5. Replies
    4
    Views
    1,254

    I am not sure I follow your question. You will...

    I am not sure I follow your question. You will have to call the ifmFastInput.IncEncoder cyclicly if you wish to receive the data from the block. It will handle the configuration of setting the...
  6. Replies
    1
    Views
    1,157

    You have to create a Local Device in the J1939...

    You have to create a Local Device in the J1939 Manager. Then have it transmit the Request PGN 59904.

    FYI, all engines are that way, the hours has always been a request.
  7. Replies
    2
    Views
    960

    You have to use the RCAN library in the CR1081...

    You have to use the RCAN library in the CR1081 and do all the transmits and receives to the CR0401. There is no CAN based Network Variables in Codesys V2.3.
  8. Replies
    1
    Views
    1,952

    No manuals yet. Hoping to see something in the...

    No manuals yet. Hoping to see something in the new year. The units aren't officially released yet.
  9. Replies
    2
    Views
    2,727

    https://www.ifm.com/us/en/product/CR721S?tab=docum...

    https://www.ifm.com/us/en/product/CR721S?tab=documents

    Then click on
    Target and documentation package

    That will take you to the package and the manuals.
  10. Replies
    3
    Views
    1,991

    We would have to look at your .pro file to see...

    We would have to look at your .pro file to see what is going on.
  11. Replies
    4
    Views
    2,259

    Thank you for the update. Good to know about the...

    Thank you for the update. Good to know about the IP address.
  12. Replies
    4
    Views
    2,259

    Not sure why you are importing it. Make a...

    Not sure why you are importing it. Make a project with both devices then add the network variables. I have multiple projects running with Network Variables. I have never run into an issue.
  13. Replies
    5
    Views
    3,475

    Do the same thing but just add another ECU. Then...

    Do the same thing but just add another ECU. Then you will have to have a check mark next to Local Device since this will be coming from your PLC. You will have to take care that your task is 10 ms...
  14. Replies
    3
    Views
    2,157

    They moved the location. Go to the CR7xxS on...

    They moved the location.

    Go to the CR7xxS on our website (doesn't matter which country). Then click on the Downloads, then Important software downloads are available for this product

    That...
  15. Replies
    5
    Views
    3,475

    Just add the J1939 manager and ECU then add the...

    Just add the J1939 manager and ECU then add the signals you want to receive.389
  16. Replies
    5
    Views
    3,475

    No those are not available on 3.5. With 3.5 you...

    No those are not available on 3.5. With 3.5 you get the J1939 Manager from Codesys.
  17. Replies
    3
    Views
    2,157

    I don't know why the website is not updated. ...

    I don't know why the website is not updated. That is managed by a different group that what manages the forum. I had already submitted this, hopefully it will be updated soon.
  18. Replies
    1
    Views
    1,686

    Please contact your local ifm support for items...

    Please contact your local ifm support for items related to safety applications.
  19. Replies
    1
    Views
    1,901

    The only option is to use Maintenance Tool and do...

    The only option is to use Maintenance Tool and do a Software/Commands/Force Bootloader Mode.
  20. I don't know. I would have your local ifm...

    I don't know. I would have your local ifm representative remote into your PC to see what is going on there.
  21. How many times do you scan? For me it never...

    How many times do you scan? For me it never shows up on the first time. I usually have to scan a few times. Looks like you have everything setup correctly.

    The scan only finds devices that...
  22. What is the IP address of your PC? Did you...

    What is the IP address of your PC? Did you change it to the same subnet? Also does your Codesys Target match the firmware on the PLC?
  23. Replies
    1
    Views
    2,726

    You are using the wrong libraries, no big deal. ...

    You are using the wrong libraries, no big deal.

    You need to use the NT libraries, they are located here:
    C:\Program Files (x86)\ifm electronic\CoDeSys V2.3\Targets\ifm\Library\ifm_J1939_NT
  24. I wonder if the firmware is old enough that it...

    I wonder if the firmware is old enough that it doesn't support the Read Channel Parameters. This feature will not work if you do not have firmware on the PLC as well.
  25. How old is the PLC? Can read the Identity?

    How old is the PLC? Can read the Identity?
Results 1 to 25 of 305
Page 1 of 13 1 2 3 4