  1. Replies
    0
    Views
    33

    CR721S ifmOutPWM.CurrentControl

    Hello,
    I'm using a CR721S and I have some troubles with ifmOutPWM.CurrentControl FB. The status of the output is always in STAT_PREPARING. It looks like that is not able to configure the output....
  2. Replies
    1
    Views
    173

    J1939 DM1 signal on CR711S

    Hello,
    using CR711S I have tried to map DM1 signal of diesel motor by J1939 driver. On Codesys, however I have seen that there is only the first DM1 message available (see picture attached).
    Is...
  3. Replies
    0
    Views
    224

    CR7132 Sampling Trace

    Hello,
    I need to monitor some values from a CR7132 PLC and I'd like to use the Sampling Trace feature on CoDeSys, but each time that I try to start the sampling the PLC stops!
    I've seen that...
  4. Replies
    2
    Views
    378

    Fixed. There was a misunderstanding with the...

    Fixed.
    There was a misunderstanding with the polarity of service pins. In firmware update manual there was indicated service 0 -GND and Service 1 - VBB; but if you want to access at SERVICE menu,...
  5. Replies
    2
    Views
    378

    CR1203 backup/restore from usb

    Hello,
    is it available some procedute to backup and restore a CR1203 like the old model CR1201, using a USB pendrive?

    BR
  6. Replies
    1
    Views
    592

    FIXED On Safety side, also if it isn't used,...

    FIXED
    On Safety side, also if it isn't used, there was IoStandard Library updated to 3.5.15.0 version. I have corrected to 3.5.10.0 and now works.
  7. Replies
    1
    Views
    592

    CR721S Safety download

    392

    Hello,
    I have tried to download a safety program on a CR721S (Safety Side). The download starts but at the end I had 2 errors (IOMGRLOCKENTER and IOMGRLOCKLEAVE see the picture).
    I have...
  8. Replies
    4
    Views
    859

    Thank you. I was quite sure about it, because the...

    Thank you. I was quite sure about it, because the system works simply using the FB but there were some doubts on manual interpretation.
  9. Replies
    4
    Views
    859

    Right, the execution of FB...

    Right, the execution of FB ifmFastInput.IncEncoder has done cyclic and I get also the results, but I'd like to be sure that the FB handle internally the input setting as high speed input.
    BR
  10. Replies
    4
    Views
    859

    CRXXS Codesys 3.5 FB IncEncoder

    Dear all,
    using FB ifmFastInput.IncEncoder for a couple of fast input, is it necessary to configure, at the beginning of first PLC cycle, the input as frequency input or the Function block do it...
  11. Replies
    1
    Views
    840

    CR711S J1939 PGN request

    On Stage V Engine the hours value (PGN 65253 in J1939 protocol) is available only on request. How can I request this data with Codesys 3.5 (for a CR711S)?

    BR
  12. Thread: ecomatDisplay

    by sbiughy
    Replies
    1
    Views
    1,479

    ecomatDisplay

    Dear All,
    have someone the programming manual or any useful stuff for the new CR1203?

    BR
  13. Replies
    1
    Views
    1,853

    Do you mean to copy a pdf to a usb pen drive? In...

    Do you mean to copy a pdf to a usb pen drive? In this case, I use WinSCP software to upload or to download data from display by ethernet cable.
  14. Thread: CR1201 table

    by sbiughy
    Replies
    3
    Views
    1,562

    390 I can't send the .pro file, but as you can...

    390
    I can't send the .pro file, but as you can see from picture above, the second table show correctly empty fields for first two rows and for other rows shows the variable name. The array names...
  15. Thread: CR1201 table

    by sbiughy
    Replies
    3
    Views
    1,562

    The project is made with Codesys 2.3

    The project is made with Codesys 2.3
  16. Thread: CR1201 table

    by sbiughy
    Replies
    3
    Views
    1,562

    CR1201 table

    In a CR1201 page I've inserted two tables that use two different arrays. When I go online with the display everything looks ok, but on the device the second table shows in the rows the variable name...
  17. Replies
    4
    Views
    1,744

    I can't make a project with both devices because...

    I can't make a project with both devices because one device has different service pack of Codesys v3.5. Anyway the problem was on broadcast setting in network variable. The default 255.255.255.255 on...
  18. Replies
    4
    Views
    1,744

    UDP Network Variable with CR721S

    I'm setting up a network variable communication via Ethernet, but looks like that the ifm PLC is not able to read the packages sent from another controller. Sometimes looks that the ifm PLC reads the...
  19. Replies
    5
    Views
    2,741

    Ok to receive message, but I have some doubt to...

    Ok to receive message, but I have some doubt to manage the TSC1 messages to send Speed reference to the engine
  20. Replies
    5
    Views
    2,741

    Are available a basic example of J1939 for a...

    Are available a basic example of J1939 for a CR7nnS PLC?

    BR
  21. Thread: CR721S Package

    by sbiughy
    Replies
    3
    Views
    1,729

    It's still not updated on IFM Italy web site. Is...

    It's still not updated on IFM Italy web site.
    Is it possible to share the last package for CR7XXS here?

    BR
  22. Replies
    5
    Views
    2,741

    CoDeSys 3.5 SP11 Library

    Dear all,
    ara available some kind of motors libraries on Codesys 3.5? On old version of Codesys 2.3 was available a lot of libraries for J1939 communication for different motors as Caterpillar,...
  23. Thread: CR721S Package

    by sbiughy
    Replies
    3
    Views
    1,729

    CR721S Package

    Dear All,
    in ifm site there is available the CR721S firmware available at V3.0.0.3, but the package for CoDeSys is still V2.8.2.3. When I have updated the PLC to V3.0.0.3 I was not able anymore to...
  24. Replies
    2
    Views
    2,229

    CR721S programming manual

    Hello,
    I can't find the programming manual of CR721S on IFM site. Could you help me?
  25. Replies
    1
    Views
    1,362

    CR711S safety output management

    Hello,
    I'm doing some test on safety side with a CR7111S PLC with v2.9.0.0 firmware. On safety application I don't see any way to command an output, I can't find any access to %Q memory access. Is...